DIMENSIONS TOLERANCES OF FLANGES (in mm)
  Welding neck
 
     
* outside diameter O.D. 600 if smaller  
+ 1.6
_
    O.D. over 600  
+ 3.1
_
         
         
    250 and smaller  
+ 0.7
_
  inside diameter 12 though 450  
+ 1.6
_
  (bore) 500 and larger
+ 3.1
– 1.6
         
         
    1.6 raised face
+ 0.4
_
 
  diameter of 6.3 raised face tounge &    
  contact face groove male and female
+ 0.4
_
 
         
         
* diameter of hub 125 and smaller
+ 2.2
– 0.7
  at point of weding 150 and larger
+ 4.0
– 0.7
         
         
  Thickness 450 and smaller
+ 3.1
– 0.0
    500 and larger
+ 4.7
– 0.0
         
  length through 250 and smaller
+ 1.6
_
  hub 300 and larger
+ 3.1
_
       
       
  bolt circle 600 and smaller
+ 0.7
_
    600 and larger
+ 1.6
_
       
  drilling bolt hole spacing
+ 0.7
_
     
     
  eccenticity with respect  
  to bore   0.70 max
     
  Threaded, Slip on lap joint,
Socket welding and blind
   
         
* outside diameter O.D. 600 or smaller  
+ 1.6
_
    O.D. over 600  
+ 3.1
_
       
  inside diameter threaded : to stand gauge limit
  (bore) slop on .lap joint : socket-welding
    250 and smaller
+ 0.7
– 0.0
    300 and larger
+ 1.6
– 0.0
         
    threaded  
  diameter of 250 and smaller
+ 0.7
– 0.0
  counter bore 300 and larger
+ 1.6
– 0.0
         
* outside diameter 300 and smaller
+ 2.3
– 1.6
  of hub 350 and larger
+ 3.1
_
         
  diameter of 1.6 raised face
+ 0.7
_
  contact face 6.3 raised fact tongue & grooved
    male & female  
+ 0.4
_
         
  Thickness 450 and smaller
+ 3.1
– 0.0
  hub 500 and larger
+ 4.7
– 0.0
       
* length through 450 and smaller
+ 3.0
– 1.6
  hub 500 and larger
+ 4.8
– 1.6
       
    bolt circle
+ 1.6
_
       
       
  drilling bolt hole spacing
+ 0.7
_
       
  eccenticity with respect    
  to bore   0.70 max
     
H Not covered by ANSI – B 16.5